Every dental practice that operates a CBCT scanner in the UK must maintain a CBCT radiation protection file. This is not a best-practice suggestion. It is a regulatory requirement under the Ionising Radiation (Medical Exposure) Regulations 2017 (IR(ME)R), and CQC inspectors actively check for it. In this guide, we explain exactly what your file should contain and how to organise it. We also cover where outsourced reporting fits into your compliance framework.
Quick Answer: What Is a CBCT Radiation Protection File?
A CBCT radiation protection file is a structured collection of documents that demonstrates your practice’s compliance with radiation safety regulations. At a minimum, it should include your employer’s procedures, local rules, and diagnostic reference levels (DRLs). It must also contain quality assurance (QA) records, training logs, and evidence of Radiation Protection Adviser (RPA) consultation. CQC expects this file to be complete, current, and readily accessible during inspections.
What IR(ME)R 2017 Requires Dental Practices to Document
IR(ME)R 2017 places specific duties on the employer, the practitioner, the operator, and the referrer. As a practice owner operating a CBCT scanner, you are the employer under IR(ME)R. Consequently, you hold primary responsibility for establishing and maintaining written procedures that govern every medical exposure.
The regulations require you to document procedures covering patient identification, referral criteria, and justification of exposures. You must also address clinical evaluation, pregnancy enquiries, dose assessment, and incident reporting. Furthermore, you must appoint duty holders in writing and maintain evidence of their entitlement to act in each role.
These written procedures form the backbone of your radiation protection file. Without them, your practice cannot demonstrate IR(ME)R compliance during a CQC inspection.
The 18 Employer’s Procedures at the Heart of Your CBCT Radiation Protection File
The Scottish Dental Clinical Effectiveness Programme (SDCEP) provides a widely adopted framework of 18 employer’s procedures (EP1 to EP18) that dental practices should implement. While SDCEP is a Scottish body, its radiation protection templates are recognised and used across the UK as a practical standard for IR(ME)R compliance.
These 18 procedures cover the full lifecycle of a CBCT exposure:
Duty holder management (EP1 to EP3): Procedures for the entitlement of practitioners, operators, and referrers. Specifically, each duty holder must have documented evidence of their qualifications, training, and authorisation to act in their designated role.
Referral and justification (EP4 to EP6): Procedures for accepting referrals, justifying exposures against clinical need, and confirming that CBCT is the appropriate imaging modality. Notably, the FDI World Dental Federation states that CBCT should never serve as a routine screening tool. Every exposure must be individually justified based on clinical indication.
Patient safety (EP7 to EP9): Procedures for patient identification, pregnancy status enquiries, and managing exposures for female patients of childbearing age.
Dose and image quality (EP10 to EP12): Procedures for dose assessment, diagnostic reference levels, and clinical evaluation of images. In particular, your file should record the DRLs you apply and evidence that you review doses periodically.
Governance and audit (EP13 to EP18): Procedures for clinical audit, equipment QA testing, incident and near-miss reporting, document control, record keeping, and patient information. Additionally, you must have a procedure for reviewing and updating the procedures themselves on a regular cycle.
Each procedure should be documented, dated, and signed by the relevant duty holder. Both SDCEP and BDA offer downloadable templates that you can adapt to your specific practice and equipment.
Local Rules, Diagnostic Reference Levels and Dose Records
Beyond the employer’s procedures, your radiation protection file must contain your practice’s local rules. These are specific to your premises and your CBCT equipment. Local rules should describe the controlled and supervised areas around your scanner. They must also include working instructions for operators and contingency plans for equipment faults or radiation incidents.
Your Radiation Protection Adviser should help you draft these local rules. Moreover, the RPA’s written report from their most recent consultation visit should also sit in your file as evidence of expert oversight.
Diagnostic reference levels are another essential component. For CBCT, DRLs help you benchmark your scanner’s dose output against national standards. You should record the DRLs you apply for each scan protocol. Compare your actual doses against these levels and investigate any consistent exceedances. This process supports the ALARP principle: keeping radiation doses as low as reasonably practicable.
QA Protocols and Training Records
Your CBCT radiation protection file should also contain evidence of routine quality assurance testing. CQC inspectors specifically look for this documentation. QA records should include results from regular constancy tests and annual critical examinations by a medical physics expert (MPE). Include any remedial actions taken when tests reveal issues.
Training records are equally important. Every person who operates your CBCT scanner, justifies an exposure, or evaluates a scan must hold appropriate training and competency evidence. For operators, this typically means an IR(ME)R operator training certificate specific to CBCT. For practitioners, you need evidence of training in CBCT justification and clinical evaluation.
Therefore, your file should contain copies of all training certificates and CPD records relevant to radiation protection. Also include a log showing when each duty holder’s training was last updated.
What CQC Inspectors Expect During a Radiation Protection Inspection
CQC has published clear guidance on what it checks during dental radiation inspections. According to CQC’s published guidance, inspectors look for evidence that your practice has consulted an RPA and registered with HSE where required. They also check that you maintain equipment through regular testing and that all staff hold appropriate training.
Importantly, CQC expects these arrangements to be “documented in a radiation file or folder.” This is not about ticking boxes on the day of inspection. Instead, it means maintaining a living document that reflects your current practice. An outdated file with expired training certificates or missing QA records will raise concerns.
CQC also checks that your practice has a clear compliance framework linking your written procedures to day-to-day clinical workflows. In particular, inspectors want to see that you conduct regular clinical audits of your imaging activity and act on the findings.
How Outsourced Reporting Strengthens Your Radiation Protection Compliance
One of the most challenging aspects of CBCT compliance is clinical evaluation. IR(ME)R requires that every medical exposure receives a clinical evaluation by a suitably qualified practitioner. For many dental practices, this is where outsourced reporting becomes essential.
When you use a consultant radiologist reporting service, each scan receives a formal structured report with clinical findings and recommendations. As a result, this provides clear documented evidence of clinical evaluation for your radiation protection file. It also reduces the medicolegal risk of missed pathology or incidental findings going unrecorded.
3Beam provides UK-wide consultant radiologist reporting for dental practices with their own CBCT scanners. Every report is prepared by a UK Dental Radiologist and includes structured findings that you can file directly as evidence of IR(ME)R-compliant clinical evaluation.
Frequently Asked Questions
Q: How often should I update my radiation protection file? A: Review your file at least annually. Also update it whenever you change equipment, modify scan protocols, appoint new duty holders, or receive a new RPA consultation report. CQC expects the file to reflect current practice at all times.
Q: Do I need a separate file for CBCT and conventional X-rays? A: Not necessarily. Many practices maintain a single radiation protection file covering all ionising radiation equipment. However, your CBCT-specific procedures, DRLs, and QA protocols must be clearly documented within it.
Q: Who is responsible for maintaining the file? A: As the employer under IR(ME)R 2017, the practice owner holds ultimate responsibility. You may delegate day-to-day maintenance to a radiation protection lead. However, accountability remains with the employer.
Q: Can I use downloadable templates for my employer’s procedures? A: Yes. SDCEP and BDA both provide templates that are widely accepted across the UK. However, you must adapt them to reflect your specific practice, equipment, and workflows. Generic templates left unedited will not satisfy CQC.
Q: Does outsourcing CBCT reporting count as clinical evaluation under IR(ME)R? A: Yes. A formal report from a qualified practitioner, such as a consultant radiologist, constitutes clinical evaluation under IR(ME)R. This is one of the key reasons practices choose to outsource reporting.
The Bottom Line on Your CBCT Radiation Protection File
Your CBCT radiation protection file is not a one-off compliance exercise. It is a living collection of documents that proves your practice meets its obligations under IR(ME)R 2017. At a minimum, it should contain your 18 employer’s procedures, local rules, DRL records, and QA test results. You also need training certificates, RPA consultation reports, clinical audit findings, and evidence of clinical evaluation for every CBCT exposure.
If your practice lacks a formal reporting pathway for CBCT scans, your radiation protection file has a significant gap. Outsourcing to a consultant radiologist fills that gap with documented, structured clinical evaluations. Consider how 3Beam’s UK-wide reporting service can strengthen both your compliance and your patient care.
Get Your Scans Reported by a Consultant Radiologist
Own a CBCT scanner? 3Beam provides UK-wide consultant radiologist reporting for dental practices. Every report is prepared by a UK Dental Radiologist with structured findings, clinical recommendations, and full IR(ME)R compliance documentation. Fast turnaround, no geographic limitation. Call: 0207 637 8227 | Email: info@3beam.co.uk | Learn more about our reporting service.